sentryumactive-act 30kva manual
Welcome to the SentryumActive-ACT 30kVA manual‚ your guide to understanding and operating this high-efficiency UPS system. Designed for scalability‚ it offers advanced battery management‚ compact design‚ and user-friendly controls for reliable power protection.
1.1 Overview of the SentryumActive-ACT 30kVA UPS System
The SentryumActive-ACT 30kVA UPS is a high-efficiency‚ transformerless system designed for mission-critical applications. It offers 96.5% online efficiency‚ full-rated power (kW = kVA)‚ and a compact footprint of 0.35m². Ideal for data centers‚ it supports non-linear loads and blade servers. The system operates in online double conversion mode‚ ensuring reliable power protection. Scalable with optional battery packs‚ it provides flexibility for varying runtime needs‚ making it a robust solution for demanding environments.
1.2 Importance of the Manual for Installation and Operation
This manual is essential for the proper installation‚ configuration‚ and operation of the SentryumActive-ACT 30kVA UPS. It provides detailed instructions‚ safety guidelines‚ and troubleshooting steps to ensure optimal performance. By following the manual‚ users can avoid installation errors‚ maintain system efficiency‚ and extend the lifespan of the UPS. It also serves as a reference for routine maintenance and technical specifications‚ ensuring compliance with safety standards and operational best practices.
Key Features of the SentryumActive-ACT 30kVA UPS
The SentryumActive-ACT 30kVA UPS offers high efficiency (up to 96.5%)‚ compact design (0.35m² footprint)‚ scalability with up to 8 units for redundancy‚ and advanced monitoring via a 5″ touchscreen.
2.1 High Efficiency and Power Factor
The SentryumActive-ACT 30kVA UPS achieves up to 96.5% efficiency in online double-conversion mode‚ minimizing energy waste. With a unity power factor‚ it delivers full-rated power (kVA = kW)‚ ensuring optimal performance. Advanced components like dual-core DSP processors and high-frequency inverters enable reliable operation‚ even at temperatures up to 40°C‚ making it ideal for mission-critical applications with non-linear loads.
2.2 Compact Design and Footprint
The SentryumActive-ACT 30kVA UPS features a compact design with a footprint of less than 0.35m² and dimensions of 380mm x 850mm x 1025mm (W x D x H). This space-saving layout makes it ideal for small data centers or mission-critical applications. The absence of internal batteries further reduces its physical size‚ allowing for flexible installation while maintaining high performance and reliability.
2.3 Scalability and Redundancy Options
The SentryumActive-ACT 30kVA UPS supports parallel operation of up to 8 units for enhanced redundancy and scalability. This capability ensures higher reliability and flexibility for mission-critical applications; The system allows for modular expansion‚ enabling users to easily increase power capacity as their needs grow. Redundancy options provide fail-safe operation‚ minimizing downtime and ensuring continuous power protection for sensitive equipment.
2.4 Advanced Control and Monitoring
The SentryumActive-ACT 30kVA UPS features a colored graphic touchscreen display for intuitive monitoring and control. It supports multi-platform communication via USB‚ RS232‚ and SNMP interfaces‚ enabling remote monitoring and management. The system provides real-time data on input/output parameters‚ battery status‚ and load conditions. Advanced DSP processors ensure precise control‚ while high-frequency inverters optimize performance. These tools enhance operational efficiency and simplify system oversight.
Technical Specifications of the SentryumActive-ACT 30kVA
Rated power: 30kVA/30kW‚ efficiency up to 96.5%‚ unity power factor‚ compact footprint‚ and scalable design for mission-critical applications‚ ensuring reliable power protection and optimal performance.
3.1 Electrical Specifications
The SentryumActive-ACT 30kVA UPS operates at a rated power of 30kVA/30kW‚ with an input voltage of 380/400/415 V three-phase. It achieves an exceptional efficiency of 96.5% in online double-conversion mode and features a unity power factor‚ ensuring minimal energy loss. The system supports a wide range of operational modes‚ including Online‚ Eco‚ and Smart Active‚ and is designed to handle non-linear loads effectively. The battery charger provides 6 Amps‚ with a runtime of 6 minutes at full load‚ and the UPS is optimized for temperatures up to 40°C‚ making it ideal for mission-critical applications.
3.2 Physical Dimensions and Weight
The SentryumActive-ACT 30kVA UPS measures 380mm x 850mm x 1025mm (W x D x H)‚ with a footprint of less than 0.35m² and a volume of 0.33m³. It weighs approximately 78kg without batteries and 112kg with batteries. Its compact design makes it ideal for small data centers or mission-critical applications‚ ensuring space efficiency without compromising performance.
3.3 Battery and Runtime Information
The SentryumActive-ACT 30kVA UPS provides a standard runtime of 6 minutes at full load. It supports optional battery extension packs for extended autonomy‚ allowing flexible runtime configurations. The system accommodates 1 or 2 internal battery strings‚ with the option to add external batteries for increased backup time. The battery charger delivers 6 Amps as standard‚ ensuring efficient charging and reliable power protection during outages.
Operating Modes of the SentryumActive-ACT 30kVA
The SentryumActive-ACT 30kVA UPS offers three operating modes: Online‚ Eco‚ and Smart Active. Each mode is designed to optimize efficiency‚ reliability‚ and performance for varying power needs.
4.1 Online Mode
The Online Mode ensures continuous power protection by converting AC to DC and back to AC‚ providing a stable output. This double-conversion technology offers high efficiency‚ reaching up to 96.5%‚ and delivers full-rated power with unity power factor. Ideal for critical applications‚ Online Mode minimizes energy waste and safeguards against power disturbances‚ making it suitable for data centers and mission-critical systems requiring reliable power supply.
4.2 Eco Mode
Eco Mode optimizes energy efficiency by switching to bypass operation when input power is stable‚ reducing energy consumption. This mode maintains high efficiency while ensuring reliable power protection. It is ideal for environments with stable mains power‚ offering a balance between energy savings and protection. The system still maintains a unity power factor and quickly switches to double-conversion mode if power issues arise‚ ensuring continuous protection without compromising performance.
4.3 Smart Active Mode
Smart Active Mode combines high efficiency with optimal performance‚ dynamically managing power conditions to minimize energy waste. This adaptive mode ensures reliable power delivery while maintaining high availability. It is ideal for critical applications‚ offering a balance between efficiency and performance. The system intelligently adjusts to load conditions‚ ensuring consistent power quality and minimizing switching losses. This mode is designed for demanding environments‚ providing both energy savings and operational reliability.
Installation and Maintenance Guidelines
This section provides essential guidelines for installing and maintaining the SentryumActive-ACT 30kVA UPS. Ensure proper site selection‚ avoid extreme temperatures‚ and perform routine checks for optimal performance.
5.1 Pre-Installation Considerations
Before installing the SentryumActive-ACT 30kVA UPS‚ ensure the site meets environmental requirements‚ including proper ventilation and temperature control. Select a location with adequate space for airflow and easy access. Verify the power supply matches the system’s specifications and ensure grounding is correctly configured. Check for compatibility with existing infrastructure and plan for future scalability. Prepare the area to avoid dust and moisture‚ and ensure all safety precautions are in place to prevent accidents during installation.
5.2 Step-by-Step Installation Process
Begin by positioning the UPS in a suitable location‚ ensuring proper ventilation and accessibility. Connect the battery cables first‚ followed by the input and output power cables. Configure the communication ports and settings as required. Perform a self-test to verify system functionality. Finally‚ power on the UPS and monitor its operation to ensure everything runs smoothly. Always refer to the manual for specific wiring and start-up procedures.
5.3 Routine Maintenance and Servicing
Regular maintenance ensures optimal performance and longevity of the SentryumActive-ACT 30kVA UPS. Inspect battery health and connections monthly‚ and clean dust filters every three months. Update firmware periodically to maintain functionality. Check for loose connections and worn-out components. Schedule annual professional servicing for in-depth diagnostics. Keep a maintenance log to track activities and plan future servicing‚ ensuring uninterrupted power protection and system reliability.
Troubleshooting Common Issues
This section guides you through identifying and resolving common faults‚ such as power failures or system malfunctions‚ ensuring minimal downtime and optimal UPS performance.
6.1 Identifying Common Faults
Identifying common faults in the SentryumActive-ACT 30kVA UPS involves monitoring system indicators and error messages. Issues like battery failures‚ overheating‚ or communication errors can arise. Check for alarm sounds‚ LED status‚ or messages on the touchscreen display. Regularly review event logs to detect recurring problems early. Addressing these faults promptly ensures system reliability and prevents potential downtime or data loss.
6.2 Solving Power-Related Problems
Power-related issues in the SentryumActive-ACT 30kVA UPS can often be resolved by checking input voltage stability‚ ensuring proper load distribution‚ and verifying battery health. If the system switches to battery mode unexpectedly‚ allow it to cool down before restarting. For persistent issues‚ review the event logs and consult the manual for troubleshooting steps. Ensure all connections are secure and consult technical support if problems persist.
6.3 Resetting and Rebooting the System
To reset the SentryumActive-ACT 30kVA UPS‚ switch to manual bypass‚ power down the system‚ and wait 10 seconds. Restart by enabling the bypass switch and allowing the UPS to resume operation. If issues persist‚ check the event logs for fault codes and consult the manual or technical support for further assistance. Ensure all connections are secure before rebooting to avoid recurring problems.
Environmental and Safety Considerations
Operate the SentryumActive-ACT 30kVA UPS in environments with temperatures up to 40°C and humidity below 80%. Ensure proper ventilation and avoid extreme conditions. Handle batteries safely‚ wearing protective gear‚ and follow disposal guidelines to minimize environmental impact.
7.1 Operating Temperature and Humidity
The SentryumActive-ACT 30kVA UPS operates effectively in temperatures ranging from 0°C to 40°C and humidity levels up to 80% non-condensing. Optimal performance is achieved in environments with consistent conditions‚ avoiding direct sunlight or extreme moisture. Ensure proper ventilation to maintain efficiency and prevent overheating. Avoid exposing the unit to corrosive or hazardous environments‚ as this may compromise system reliability and safety.
7.2 Safety Precautions for Handling
When handling the SentryumActive-ACT 30kVA UPS‚ ensure the system is powered down and disconnected from all power sources. Wear protective gear‚ including gloves and safety glasses‚ to prevent injury from sharp edges or electrical components. Avoid exposing the unit to water or extreme temperatures‚ which may damage internal parts. Properly ground the system during installation to prevent electrical hazards. Always follow the manufacturer’s guidelines to ensure safe and reliable operation‚ minimizing risks to both personnel and equipment.
Warranty and Support Information
The SentryumActive-ACT 30kVA UPS is backed by a comprehensive warranty‚ ensuring coverage for parts and labor. For technical assistance‚ contact Riello’s support team or visit their official website for detailed support options and resources.
8.1 Warranty Coverage Details
The SentryumActive-ACT 30kVA UPS is supported by a comprehensive warranty program‚ ensuring protection for parts and labor. The standard warranty period covers defects in materials and workmanship‚ providing peace of mind for users. Extended warranty options are available for increased protection. For specific terms and conditions‚ refer to the official documentation or contact Riello’s customer support team. Warranty details may vary based on regional policies and installation requirements.
8.2 Contacting Technical Support
For technical assistance‚ contact Riello’s support team via phone‚ email‚ or through their official website. The dedicated support specialists are available to address inquiries‚ provide troubleshooting guidance‚ and offer solutions. Ensure to have your UPS model and serial number ready for efficient service. Visit the official Riello UPS website for regional contact details and additional support resources. Support is available during standard business hours‚ with options for extended support in critical situations.
Downloading the Manual and Additional Resources
The official Riello UPS website offers the SentryumActive-ACT 30kVA manual and supplementary guides. Visit www.riello-ups.com or authorized distributors for genuine downloads and technical support resources.
9.1 Official Sources for the Manual
The SentryumActive-ACT 30kVA manual and additional resources are available on Riello UPS’s official website. Visit www.riello-ups.com for direct downloads. Authorized distributors and technical support portals also provide access to genuine documentation. Ensure to verify the source for authenticity to avoid unauthorized versions. The manual includes detailed installation‚ operation‚ and troubleshooting guides‚ making it essential for optimal system performance and maintenance. Always refer to official sources for the most reliable information.
9.2 Supplementary Documentation and Guides
Supplementary guides‚ such as technical notes and FAQs‚ complement the manual. These resources‚ available on Riello UPS’s website and through authorized distributors‚ provide in-depth troubleshooting‚ advanced configuration tips‚ and best practices. Additional materials include installation checklists‚ warranty details‚ and compliance certificates. These documents ensure comprehensive understanding and optimal use of the SentryumActive-ACT 30kVA system‚ enhancing user experience and system reliability.